INVERTED MICRO-SPRINKLER DESIGN CRITERIA |
psi | |
20 | 30 | |
#2 Nozzle - Pink (1/32") | ||
Flow (gph) | 7.2 | 9.0 |
(Short) Diameter at 3.0 ft ht (ft) | 5.2 | 6.1 |
#3 Nozzle - Ice (3/64") | ||
Flow (gph) | 16.8 | 20.4 |
Diameter at 6.0 ft ht (ft) | 29 | 32 |
#4 Nozzle - Light Blue (1/16") | ||
Flow (gph) | 30.0 | 36.6 |
Diameter at 6.0 ft ht (ft) | 33 | 36 |
#5 Nozzle - Beige (5/64") | ||
Flow (gph) | 46.2 | 57.0 |
Diameter at 6.0 ft ht (ft) | 38 | 40 |
#6 Nozzle - Gold (3/32") | ||
Flow (gph) | 66.6 | 81.6 |
Diameter at 6.0 ft ht (ft) | 39 | 40 |
Sprinkler performance may vary with actual field conditions. Consider friction loss through the tubing when designing for optimum performance.