Inverted Micro-Sprinkler (Metric)

INVERTED MICRO-SPRINKLER
design criteria
bar
1.38 2.07
#2 Nozzle - Pink (0.79 mm)  
Flow (L/hr) 27.3 34.1
(Short) Diameter at 0.9 m ht (m) 1.6 1.9
 
#3 Nozzle - Ice (1.19 mm)  
Flow (L/hr) 63.6 77.2
Diameter at 1.83 m ht (m) 9.0 9.6
#4 Nozzle - Light Blue (1.59 mm)  
Flow (L/hr) 113.6 138.5
Diameter at 1.83 m ht (m) 9.9 11.0
#5 Nozzle - Beige (1.98 mm)  
Flow (L/hr) 174.9 215.8
Diameter at 1.83 m ht (m) 11.7 12.1
#6 Nozzle - Gold (2.38 mm)  
Flow (L/hr) 252.1 308.9
Diameter at 1.83 m ht (m) 11.8 12.2

Sprinkler performance may vary with actual field conditions. Consider friction loss through the tubing when designing for optimum performance.