Triad™

TRIAD
DESIGN CRITERIA
psi
10 15 20 25 30 35
0 Degree Trajectory  
Flow* (gpm) 0.94 1.16 1.36 1.52 1.68 1.82
Radius Minimum Throw 1.5 ft (ft) 9.5 12.0 13.0 13.0 13.0 13.0
Radius Maximum Throw 1.5 ft (ft) 10.0 13.5 15.0 16.5 17.0 17.5
30 Degree Trajectory  
Flow* (gpm) 0.94 1.16 1.36 1.52 1.68 1.82
Radius Minimum Throw 1.5 ft (ft) 17.5 23.5 25.0 25.5 26.0 26.5
Radius Maximum Throw 1.5 ft (ft) 21.5 29.0 31.5 32.5 33.5 34.5

Sprinkler performance may vary with actual field conditions. Tree diking is recommended for best water retention. *Flow rate is for all three nozzles combined.