2009HS Impact Sprinkler (Metric)

2009HS SPRINKLER
Design Criteria
bar
2.07 2.41 2.76 3.10 3.45
#6 Nozzle - Gold (2.38 mm)  
Flow (L/hr) 304 329 352 372 -
Diameter at 0.46 m ht (m) 17.7 18.3 18.9 19.5 -
#7 Nozzle - Lime (2.78 mm)  
Flow (L/hr) 418 452 482 511 538
Diameter at 0.46 m ht (m) 18.3 18.9 19.5 20.1 20.4
#8 Nozzle - Lavender (3.18 mm)  
Flow (L/hr) 550 595 634 675 709
Diameter at 0.46 m ht (m) 18.9 19.5 20.1 20.7 21.0
#9 Nozzle - Grey (3.57 mm)  
Flow (L/hr) 700 756 809 859 904
Diameter at 0.46 m ht (m) 19.5 20.1 20.7 21.3 21.6

Sprinkler performance may vary with actual field conditions. Stream heights range from 0.46 to 0.91 m above the nozzle based on pressure and nozzle size. Minimum recommended riser height is 0.46 m.