2023HS SPRINKLER Design Criteria |
bar | ||||
2.07 | 2.41 | 2.76 | 3.10 | 3.45 | |
#6 Nozzle - Gold (2.38 mm) | |||||
Flow (L/hr) | 304 | 329 | 352 | 372 | - |
Diameter at 0.46 m ht (m) | 22.6 | 22.9 | 23.2 | 23.5 | - |
#7 Nozzle - Lime (2.78 mm) | |||||
Flow (L/hr) | 418 | 452 | 482 | 511 | 538 |
Diameter at 0.46 m ht (m) | 23.2 | 23.5 | 23.8 | 24.1 | 24.4 |
#8 Nozzle - Lavender (3.18 mm) | |||||
Flow (L/hr) | 550 | 595 | 634 | 675 | 709 |
Diameter at 0.46 m ht (m) | 23.8 | 24.1 | 24.4 | 24.7 | 25.0 |
#9 Nozzle - Grey (3.57 mm) | |||||
Flow (L/hr) | 700 | 756 | 809 | 859 | 904 |
Diameter at 0.46 m ht (m) | 24.1 | 24.4 | 24.7 | 25.0 | 25.3 |
Sprinkler performance may vary with actual field conditions. Stream heights range from 2.0 to 3.0 m above nozzle based on pressure and nozzle size. Minimum recommended riser height is 0.46 m.