4012-1 Impact Sprinkler

4012-1 Sprinkler
Design Criteria
psi
30 35 40 45 50 55 60
#10 Nozzle - Turquoise (5/32")  
Flow (gpm) 3.82 4.13 4.41 4.68 4.93 5.17 5.40
Diameter at 1.5 ft ht (ft) 73 77 80 83 86 89 91
#11 Nozzle - Yellow (11/64")  
Flow (gpm) 4.63 5.00 5.34 5.67 5.98 6.27 6.55
Diameter at 1.5 ft ht (ft) 76 80 83 86 89 92 94
#12 Nozzle - Red (3/16")  
Flow (gpm) 5.52 5.97 6.37 6.76 7.13 7.48 7.81
Diameter at 1.5 ft ht (ft) 78 82 85 88 91 94 96
#13 Nozzle - White (13/64")  
Flow (gpm) 6.50 7.02 7.49 7.95 8.38 8.80 9.19
Diameter at 1.5 ft ht (ft) 80 84 87 90 93 96 98
#14 Nozzle - Blue (7/32")  
Flow (gpm) 7.49 8.09 8.63 9.17 9.66 10.1 10.6
Diameter at 1.5 ft ht (ft) 82 86 89 93 96 99 101

Sprinkler performance may vary with actual field conditions. Stream heights range from 3.5 to 5.0 ft above nozzle based on pressure and nozzle size. Minimum recommended riser height is 1.5 ft.