5012-1 Impact Sprinkler

5012-1 SPRINKLER
Design Criteria
psi
30 35 40 45 50 55 60 65
#13 Nozzle - White (13/64")  
Flow (gpm) 6.50 7.02 7.49 7.95 8.36 8.80 9.19 9.55
Diameter at 1.5 ft ht (ft) 77 83 89 93 97 100 103 105
#14 Nozzle - Blue (7/32")  
Flow (gpm) 7.49 8.09 8.63 9.17 9.66 10.1 10.6 11.0
Diameter at 1.5 ft ht (ft) 79 85 91 95 99 102 105 107
#15 Nozzle - Dark Brown (15/64")  
Flow (gpm) 8.51 9.19 9.81 10.4 11.0 11.5 12.0 12.5
Diameter at 1.5 ft ht (ft) 81 87 93 97 101 104 107 109
#16 Nozzle - Orange (1/4")  
Flow (gpm) 9.63 10.4 11.1 11.8 12.4 13.0 13.6 14.2
Diameter at 1.5 ft ht (ft) 83 89 95 99 103 106 109 111
#17 Nozzle - Dark Green (17/64")  
Flow (gpm) 10.7 11.6 12.3 13.1 13.8 14.5 15.1 15.7
Diameter at 1.5 ft ht (ft) 85 91 96 100 105 108 111 113
#18 Nozzle - Purple (9/32")  
Flow (gpm) 11.9 12.9 13.7 14.6 15.4 16.1 16.8 17.5
Diameter at 1.5 ft ht (ft) 87 92 97 101 107 110 113 114

Sprinkler performance may vary with actual field conditions. Stream heights range from 3.5 to 6.0 ft above nozzle based on pressure and nozzle size. Minimum recommended riser height is 1.5 ft.