5023-1 Impact Sprinkler

5023-1 SPRINKLER
Design Criteria
psi
30 35 40 45 50 55 60 65
#13 Nozzle - White (13/64")  
Flow (gpm) 6.50 7.02 7.49 7.95 8.38 8.80 9.19 9.55
Diameter at 1.5 ft ht (ft) 92 95 98 100 102 103 104 105
Diameter at 6.0 ft ht (ft) 99 102 104 106 108 110 112 114
#14 Nozzle - Blue (7/32")  
Flow (gpm) 7.49 8.09 8.63 9.17 9.66 10.1 10.6 11.0
Diameter at 1.5 ft ht (ft) 94 98 101 103 105 106 107 108
Diameter at 6.0 ft ht (ft) 101 104 107 110 112 114 116 118
#15 Nozzle - Dark Brown (15/64")  
Flow (gpm) 8.51 9.19 9.81 10.4 11.0 11.5 12.0 12.5
Diameter at 1.5 ft ht (ft) 96 100 103 106 107 108 109 110
Diameter at 6.0 ft ht (ft) 102 106 109 112 114 116 118 120
#16 Nozzle - Orange (1/4")  
Flow (gpm) 9.63 10.4 11.1 11.8 12.4 13.0 13.6 14.2
Diameter at 1.5 ft ht (ft) 98 102 105 108 109 110 111 112
Diameter at 6.0 ft ht (ft) 103 107 111 114 116 118 120 122
#17 Nozzle - Dark Green (17/64")  
Flow (gpm) 10.7 11.6 12.3 13.1 13.8 14.5 15.1 15.7
Diameter at 1.5 ft ht (ft) 99 104 107 110 111 112 113 114
Diameter at 6.0 ft ht (ft) 104 108 112 115 118 120 122 124
#18 Nozzle - Purple (9/32")  
Flow (gpm) 11.9 12.9 13.7 14.6 15.4 16.1 16.8 17.5
Diameter at 1.5 ft ht (ft) 100 105 109 112 113 114 115 116
Diameter at 6.0 ft ht (ft) 105 109 113 116 119 122 124 126

Sprinkler performance may vary with actual field conditions. Stream heights range from 7.0 to 11.5 ft above nozzle based on pressure and nozzle size. Minimum recommended riser height is 1.5 ft.