5023-1 Impact Sprinkler (Metric)

5023-1 SPRINKLER
Design Criteria
BAR
2.07 2.42 2.76 3.10 3.45 3.80 4.14 4.49
#13 Nozzle - White (5.16 mm)  
Flow (L/hr) 1476 1594 1701 1806 1903 1999 2087 2169
Diameter at 0.46 m ht (m) 28.0 29.0 29.9 30.5 31.1 31.4 31.7 32.0
Diameter at 1.83 m ht (m) 30.2 31.1 31.7 32.3 32.9 33.5 34.1 34.7
#14 Nozzle - Blue (5.56 mm)  
Flow (L/hr) 1701 1837 1960 2083 2194 2294 2408 2498
Diameter at 0.46 m ht (m) 28.7 29.9 30.8 31.4 32.0 32.3 32.6 32.9
Diameter at 1.83 m ht (m) 30.8 31.7 32.6 33.5 34.1 34.7 35.4 36.0
#15 Nozzle - Dark Brown (5.95 mm)  
Flow (L/hr) 1933 2087 2228 2362 2498 2612 2725 2839
Diameter at 0.46 m ht (m) 29.3 30.5 31.4 32.3 32.6 32.9 33.2 33.5
Diameter at 1.83 m ht (m) 31.1 32.3 33.2 34.1 34.7 35.4 36.0 36.6
#16 Nozzle - Orange (6.35 mm)  
Flow (L/hr) 2187 2362 2521 2680 2816 2953 3089 3225
Diameter at 0.46 m ht (m) 29.9 31.1 32.0 32.9 33.2 33.5 33.8 34.1
Diameter at 1.83 m ht (m) 31.4 32.6 33.8 34.7 35.4 36.0 36.6 37.2
#17 Nozzle - Dark Green (6.75 mm)  
Flow (L/hr) 2430 2635 2794 2975 3134 3293 3430 3566
Diameter at 0.46 m ht (m) 30.2 31.7 32.6 33.5 33.8 34.1 34.4 34.7
Diameter at 1.83 m ht (m) 31.7 32.9 34.1 35.1 36.0 36.6 37.2 37.8
#18 Nozzle - Purple (7.14 mm)  
Flow (L/hr) 2703 2930 3112 3316 3498 3657 3816 3975
Diameter at 0.46 m ht (m) 30.5 32.0 33.2 34.1 34.4 34.7 35.1 35.4
Diameter at 1.83 m ht (m) 32.0 33.2 34.4 35.4 36.3 37.2 37.8 38.4

Sprinkler performance may vary with actual field conditions. Stream heights range from 2.1 to 3.5 m above nozzle based on pressure and nozzle size. Minimum recommended riser height is 0.46 m.