7025RD-1 Impact Sprinkler

7025RD-1 SPRINKLER
Design Criteria
psi
40 50 60 70
#14 Nozzle (7/32")  
Flow (gpm) 8.66 9.69 10.6 11.5
Diameter at 1.5 ft ht (ft) 111 115 119 123
Diameter at 6.0 ft ht (ft) 118 124 128 130
#16 Nozzle (1/4")  
Flow (gpm) 11.4 12.8 14.0 15.1
Diameter at 1.5 ft ht (ft) 117 123 129 133
Diameter at 6.0 ft ht (ft) 126 131 136 138
#18 Nozzle (9/32")  
Flow (gpm) 14.2 15.9 17.4 18.8
Diameter at 1.5 ft ht (ft) 124 129 139 144
Diameter at 6.0 ft ht (ft) 132 137 144 147
#20 Nozzle (5/16")  
Flow (gpm) 17.1 19.2 21.0 22.7
Diameter at 1.5 ft ht (ft) 130 137 146 153
Diameter at 6.0 ft ht (ft) 137 143 151 155
#22 Nozzle (11/32")  
Flow (gpm) 20.5 22.9 25.1 27.1
Diameter at 1.5 ft ht (ft) 133 148 157 162
Diameter at 6.0 ft ht (ft) 141 150 159 164
#24 Nozzle (3/8")  
Flow (gpm) 23.9 26.7 29.3 31.6
Diameter at 1.5 ft ht (ft) 138 151 160 169
Diameter at 6.0 ft ht (ft) 145 155 164 170

Sprinkler performance may vary with actual field conditions. Diameters shown are for standard straight bore nozzles and stream straightening vanes. Other nozzles and/or vane combinations are available. Consult factory for specific performance data. Stream heights range from 8.5 to 15.5 ft above nozzle based on pressure and nozzle size. Minimum recommended riser height is 1.5 ft.