7025RD-1 Impact Sprinkler (Metric)

7025RD-1 SPRINKLER
Design Criteria
bar
2.76 3.45 4.14 4.83
#14 Nozzle (5.56 mm)  
Flow (L/hr) 1967 2201 2408 2612
Diameter at 0.46 m ht (m) 33.8 35.1 36.3 37.5
Diameter at 1.83 m ht (m) 36.0 37.8 39.0 39.6
#16 Nozzle (6.35 mm)  
Flow (L/hr) 2589 2907 3180 3430
Diameter at 0.46 m ht (m) 35.7 37.5 39.3 40.5
Diameter at 1.83 m ht (m) 38.4 39.9 41.5 42.1
#18 Nozzle (7.14 mm)  
Flow (L/hr) 3225 3611 3952 4270
Diameter at 0.46 m ht (m) 37.8 39.3 42.4 43.9
Diameter at 1.83 m ht (m) 40.2 41.8 43.9 44.8
#20 Nozzle (7.94 mm)  
Flow (L/hr) 3884 4361 4770 5156
Diameter at 0.46 m ht (m) 39.6 41.8 44.5 46.6
Diameter at 1.83 m ht (m) 41.8 43.6 46.0 47.2
#22 Nozzle (8.73 mm)  
Flow (L/hr) 4656 5201 5701 6155
Diameter at 0.46 m ht (m) 40.5 45.1 47.9 49.4
Diameter at 1.83 m ht (m) 43.0 45.7 48.5 50.0
#24 Nozzle (9.53 mm)  
Flow (L/hr) 5428 6064 6655 7177
Diameter at 0.46 m ht (m) 42.1 46.0 48.8 51.5
Diameter at 1.83 m ht (m) 44.2 47.2 50.0 51.8

Sprinkler performance may vary with actual field conditions. Diameters shown are for standard straight bore nozzles and stream straightening vanes. Other nozzles and/or vane combinations are available. Consult factory for specific performance data. Stream heights range from 2.6 to 4.7 m above nozzle based on pressure and nozzle size. Minimum recommended riser height is 0.46 m.