8025HR-2 Impact Sprinkler

8025HR-2 SPRINKLER
Design Criteria
psi
40 50 60 70
26x14
#26 Nozzle (13/32") x #14 Spreader Nozzle - Blue (7/32")
 
Flow (gpm) 39.4 44.0  48.2  52.1 
Diameter at 1.5 ft ht (ft) 142 152  161  166
Diameter at 6.0 ft ht (ft) 157 164  169  173
28x14
#28 Nozzle (7/16") x #14 Spreader Nozzle - Blue (7/32")
 
Flow (gpm) 42.0  46.9  51.4  55.6
Diameter at 1.5 ft ht (ft) 148 157  166  171
Diameter at 6.0 ft ht (ft) 161  168  173  177
30x14
#30 Nozzle (15/32") x #14 Spreader Nozzle - Blue (7/32")
 
Flow (gpm) 45.9  51.4  56.3 60.8 
Diameter at 1.5 ft ht (ft) 153  162  170 175 
Diameter at 6.0 ft ht (ft) 165 172  177  181 
32x16
#32 Nozzle (1/2") x #16 Spreader Nozzle - Orange (1/4")
 
Flow (gpm) 53.7  60.0  65.8 71.0
Diameter at 1.5 ft ht (ft) 156  165 173  179
Diameter at 6.0 ft ht (ft) 169  176  181 185
34x16
#34 Nozzle (17/32") x #16 Spreader Nozzle - Orange (1/4")
 
Flow (gpm) 59.2  66.2 72.5  78.3
Diameter at 1.5 ft ht (ft) 159  168  176 183 
Diameter at 6.0 ft ht (ft) 172  179 184  188
36x16
#36 Nozzle (9/16") x #16 Spreader Nozzle - Orange (1/4")
 
Flow (gpm) 65.1 72.7  79.7  86.1 
Diameter at 1.5 ft ht (ft) 161  170  178  187 
Diameter at 6.0 ft ht (ft) 175  182 187 191 
38x18
#38 Nozzle (19/32") x #18 Spreader Nozzle - Purple (9/32")
 
Flow (gpm) 71.7  80.1  87.8  94.9 
Diameter at 1.5 ft ht (ft) 163  172  180  190 
Diameter at 6.0 ft ht (ft) 178  185  190  194
40x18
#40 Nozzle (5/8") x #18 Spreader Nozzle - Purple (9/32")
 
Flow (gpm) 78.0  87.2  95.6  103.2 
Diameter at 1.5 ft ht (ft) 165  174  182  192 
Diameter at 6.0 ft ht (ft) 180 187  192  196 

Sprinkler performance may vary with actual field conditions. Diameters shown are for standard straight bore nozzles and stream straightening vanes. Other nozzles and/or vane combinations are available. Consult factory for specific performance data. Stream heights range from 12.5 to 28.0 ft above nozzle based on pressure and nozzle size. Minimum recommended riser height is 0.46 m.