DESIGN CRITERIA
Preset Operating Pressure Maximum Inlet Pressure Flow Range Inlet Sizes Outlet Sizes
PRL06 6 psi 80 psi 0.5 - 5 gpm 3/4" F NPT, 3/4" F hose 3/4" F NPT
PRL10 10 psi 90 psi 0.5 - 8 gpm 3/4" F NPT, 3/4" F hose 3/4" F NPT
PRL12 12 psi 90 psi 0.5 - 8 gpm 3/4" F NPT, 3/4" F hose 3/4" F NPT
PRL15 15 psi 95 psi 0.5 - 8 gpm 3/4" F NPT, 3/4" F hose 3/4" F NPT
PRL20 20 psi 100 psi 0.5 - 8 gpm 3/4" F NPT, 3/4" F hose 3/4" F NPT
PRL25 25 psi 105 psi 0.5 - 8 gpm 3/4" F NPT, 3/4" F hose 3/4" F NPT
PRL30 30 psi 110 psi 0.5 - 8 gpm 3/4" F NPT, 3/4" F hose 3/4" F NPT
PRL35 35 psi 115 psi 0.5 - 8 gpm 3/4" F NPT, 3/4" F hose 3/4" F NPT
PRL40 40 psi 120 psi 0.5 - 8 gpm 3/4" F NPT, 3/4" F hose 3/4" F NPT

The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.

Recommended for outdoor use only. Not NSF certified.