PRL (Metric)

PRL
DESIGN CRITERIA
Preset Operating Pressure Maximum Inlet Pressure Flow Range Inlet Sizes Outlet Sizes
PRL06 0.41 bar 5.51 bar 114 - 1136 L/hr 3/4" F NPT, 3/4" F hose 3/4" F NPT
PRL10 0.69 bar 6.20 bar 114 - 1817 L/hr 3/4" F NPT, 3/4" F hose 3/4" F NPT
PRL12 0.83 bar 6.20 bar 114 - 1817 L/hr 3/4" F NPT, 3/4" F hose 3/4" F NPT
PRL15 1.03 bar 6.55 bar 114 - 1817 L/hr 3/4" F NPT, 3/4" F hose 3/4" F NPT
PRL20 1.38 bar 6.89 bar 114 - 1817 L/hr 3/4" F NPT, 3/4" F hose 3/4" F NPT
PRL25 1.72 bar 7.24 bar 114 - 1817 L/hr 3/4" F NPT, 3/4" F hose 3/4" F NPT
PRL30 2.07 bar 7.58 bar 114 - 1817 L/hr 3/4" F NPT, 3/4" F hose 3/4" F NPT
PRL35 2.41 bar 7.93 bar 114 - 1817 L/hr 3/4" F NPT, 3/4" F hose 3/4" F NPT
PRL40 2.76 bar 8.27 bar 114 - 1817 L/hr 3/4" F NPT, 3/4" F hose 3/4" F NPT

The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 0.34 bar above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.

Recommended for outdoor use only. Not NSF certified.