PRLG (Metric)

PRLG
DESIGN CRITERIA
Preset Operating Pressure Maximum Inlet Pressure Flow Range Inlet Sizes Outlet Sizes
PRLG10 0.69 bar 6.20 bar 114 - 1590 L/hr 3/4" F NPT, 3/4" F hose 3/4" M NPT, 3/4" M hose
PRLG15 1.03 bar 6.55 bar 114 - 1590 L/hr 3/4" F NPT, 3/4" F hose 3/4" M NPT, 3/4" M hose
PRLG20 1.38 bar 6.89 bar 114 - 1590 L/hr 3/4" F NPT, 3/4" F hose 3/4" M NPT, 3/4" M hose
PRLG25 1.72 bar 7.24 bar 114 - 1590 L/hr 3/4" F NPT, 3/4" F hose 3/4" M NPT, 3/4" M hose
PRLG30 2.07 bar 7.58 bar 114 - 1590 L/hr 3/4" F NPT, 3/4" F hose 3/4" M NPT, 3/4" M hose
PRLG35 2.41 bar 7.93 bar 114 - 1590 L/hr 3/4" F NPT, 3/4" F hose 3/4" M NPT, 3/4" M hose
PRLG40 2.76 bar 8.27 bar 114 - 1590 L/hr 3/4" F NPT, 3/4" F hose 3/4" M NPT, 3/4" M hose

The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 0.34 bar above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.

Recommended for outdoor use only. Not NSF certified.