PSR-2 DESIGN CRITERIA |
Preset Operating Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
PSR-2-06 | 6 psi | 80 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
PSR-2-10 | 10 psi | 90 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
PSR-2-12 | 12 psi | 90 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
PSR-2-15 | 15 psi | 95 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
PSR-2-20 | 20 psi | 100 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
PSR-2-25 | 25 psi | 105 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
PSR-2-30 | 30 psi | 110 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
PSR-2-35 | 35 psi | 115 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
PSR-2-40 | 40 psi | 120 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
PSR-2-50 | 50 psi | 130 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.
Recommended for outdoor use only. Not NSF certified.