8025HR-1 CMS & EFF (Metric)

8025HR-1 CMS & EFF
Design Criteria
bar
2.76 3.45 4.14 4.83
#24 Nozzle (9.53 mm)  
Flow (L/hr) 5724 6405 7018 7563
Diameter at 0.46 m ht (m) 40.8 43.9 46.9 48.5
#26 Nozzle (10.32 mm)  
Flow (L/hr) 6655 7427 8154 8790
Diameter at 0.46 m ht (m) 43.3 46.3 49.1 50.6
#28 Nozzle (11.11 mm)  
Flow (L/hr) 7700 8631 9448 10198
Diameter at 0.46 m ht (m) 45.1 47.9 50.6 52.1
#30 Nozzle (11.91 mm)  
Flow (L/hr) 8767 9789 10720 11583
Diameter at 0.46 m ht (m) 46.6 49.4 51.8 53.3
#32 Nozzle (12.7 mm)  
Flow (L/hr) 9971 11129 12197 13173
Diameter at 0.46 m ht (m) 47.5 50.3 52.7 54.6
#34 Nozzle (13.49 mm)  
Flow (L/hr) 11243 12583 13786 14877
Diameter at 0.46 m ht (m) 48.5 51.2 53.6 55.8
#36 Nozzle (14.29 mm)  
Flow (L/hr) 12605 14104 15444 16694
Diameter at 0.46 m ht (m) 49.1 51.8 54.3 57.0
#38 Nozzle (15.08 mm)  
Flow (L/hr) 13605 15195 16648 17988
Diameter at 0.46 m ht (m) 49.7 52.4 54.9 57.9
#40 Nozzle (15.88 mm)  
Flow (L/hr) 15240 17034 18647 20146
Diameter at 0.46 m ht (m) 50.3 53.0 55.5 58.5

Sprinkler performance may vary with actual field conditions. Diameters shown are for standard straight bore nozzles and stream straightening vanes. Other nozzles are available. Consult factory for specific performance data. Stream heights range from 3.8 to 8.5 m above nozzle based on pressure and nozzle size.