DYNAMIC DRIVE DESIGN CRITERIA |
Low Pressure TOP (white deflector) |
High Pressure TOP (dark blue deflector) |
Low Pressure DROP (green deflector) |
High Pressure DROP (orange deflector) |
Part Circle (mustard deflector) |
Nozzle Sizes* | |||||
Nozzle number | #6 - #26 | #6 - #26 | #6 - #26 | #6 - #26 | #8 - #15 |
Nozzle orifice size | 2.38 - 10.32 mm | 2.38 - 10.32 mm | 2.38 - 10.32 mm | 2.38 - 10.32 mm | 3.18 - 5.95 mm |
Flows | |||||
Minimum | 182 L/hr | 223 L/hr | 182 L/hr | 223 L/hr | 325 L/hr |
Maximum | 3402 L/hr | 223 - 7606 L/hr | 182 - 3402 L/hr | 223 - 5892 L/hr | 325 - 1996 L/hr |
Diameters | |||||
At 0.91 m height | 7.6 - 11.9 m | 7.9 - 14.3 m | |||
At 1.83 m height | 8.2 - 14.9 m | 8.5 - 18 m | |||
At 2.74 m height | 9.4 - 15.5 m | 11.6 - 18 m | Radius 6.4 - 8.2 m | ||
At 3.66 m height | 11.0 - 15.8 m | 15.2 - 18.3 m | |||
Maximum Spacing** | |||||
At 2.74 m ground clearance | 4.6 m | 6.1 m | |||
At 3.66 m ground clearance | 3.4 m | 6.1 m | |||
Pressure at the Nozzle | |||||
Minimum and maximum | 0.69 bar | 1.03 - 3.45 bar | 0.69 bar | 1.03 - 2.07 bar | 0.69 - 2.07 bar |
*It is recommended that larger nozzle sizes be used only on soils that can handle higher application rates.
Note: When outlet spacing exceeds 3.0 m, keep Dynamic Drive sprinklers above crop canopy. This is especially important on high profile crops.
Not warranted for rigid installation on offsets or booms larger than 3.2 m.