Triad™ TRIAD DESIGN CRITERIA psi 10 15 20 25 30 35 0 Degree Trajectory Flow* (gpm) 0.94 1.16 1.36 1.52 1.68 1.82 Radius Minimum Throw 1.5 ft (ft) 9.5 12.0 13.0 13.0 13.0 13.0 Radius Maximum Throw 1.5 ft (ft) 10.0 13.5 15.0 16.5 17.0 17.5 30 Degree Trajectory Flow* (gpm) 0.94 1.16 1.36 1.52 1.68 1.82 Radius Minimum Throw 1.5 ft (ft) 17.5 23.5 25.0 25.5 26.0 26.5 Radius Maximum Throw 1.5 ft (ft) 21.5 29.0 31.5 32.5 33.5 34.5 Sprinkler performance may vary with actual field conditions. Tree diking is recommended for best water retention. *Flow rate is for all three nozzles combined.
Triad™ (Metric) TRIAD DESIGN CRITERIA bar 0.69 1.04 1.38 1.73 2.07 2.42 0 Degree Trajectory Flow* (L/hr) 213 263 309 345 382 413 Radius Minimum Throw 0.46 m (m) 2.9 3.7 4.0 4.0 4.0 4.0 Radius Maximum Throw 0.46 m (m) 3.0 4.1 4.6 5.0 5.2 5.3 30 Degree Trajectory Flow* (L/hr) 213 263 309 345 381 413 Radius Minimum Throw 0.46 m (m) 5.3 7.2 7.6 7.8 7.9 8.1 Radius Maximum Throw 0.46 m (m) 6.6 8.8 9.6 9.9 10.2 10.5 Sprinkler performance may vary with actual field conditions. Tree diking is recommended for best water retention. *Flow rate is for all three nozzles combined.